Our range of products include fixed h2o2 gas detector, eto (c2h4o) fixed gas detector, so2 fixed gas detector, ch2o fixed gas detector, hexane (c6h14) fixed gas detector and ph3 fixed gas detector.
₹ 147500 / Piece Get Latest Price
| Detector Type | Fixed Gas Detector |
| Pump | Yes |
| Country of Origin | Made in India |
| Gas Type | H2O2 |
| Brand Name | Mukta Instruments |
| Weight | 3.4kg |
| Resolution | 1PPM |
| Dimensions | 286x202x96mm |
| Measure range | 100 PPM |
| Power | 24DC |
•Gas Detected: H2O2
•Detection Principle: Electrochemical
•Measurement Range: 0–100ppm
•Accuracy: ≤±2–5% F.S. (depending on the specific sensor)
•Response Time (T90): 15–30 seconds (depending on the specific sensor)
•Repeatability: ≤±1%
•Zero Drift: ≤±1% F.S./year
•Display: 2.4-inch color display, resolution 320×240
•Display Content: Gas molecular formula, concentration, unit, etc.
•Alarm (Optional): Buzzer, alarm status prompt on screen, user-configurable high/low alarm values
•Language Options: Chinese and English
•Communication & Data Download: PC software available for downloading, storing, printing, and analyzing historical data (optional)
•Operating Temperature: –10℃ to +55℃
•Humidity Range: 0–95% RH (non-condensing)
•Materials:
•Case: Die-cast aluminium
•Sensor Housing: Aluminium alloy or 316 stainless steel
•Power Supply: 12–24V DC
•Dimensions (H×W×D): 286 × 202 × 96 mm
•Weight: 3.4 kg (3.8 kg with alarm light)
₹ 57744 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Pump | Yes |
| Humidity | 95%RH |
| Dimensions (L x W x H) | 180x150x90mm |
| Dimensions | 180x150x90mm |
| Measuring Range | 100PPM |
| Country of Origin | Made in India |
| Model Number | MI-95H1ETO |
Minimum order quantity: 10 Piece
Gas Detected: ETO C2H4O (Ethylene Oxide)
Detection Principle: Electrochemical
Measurement Range: 0–10, 50, 100 ppm (Available Measuring range: 0-200, 500, 1000ppm)
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 57744 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Pump | Yes |
| Dimensions (L x W x H) | 180x150x90mm |
| Humidity | 0-95%RH (no condensation) |
| Display Type | Digital |
| Model | MI-95H1SO2 |
| Dimensions | 180x150x90mm |
| Measuring Range | 20PPM |
| Power Source | Plug-In |
| Country of Origin | Made in India |
Gas Detected: SO₂ (Sulfur Dioxide)
Detection Principle: Electrochemical
Measurement Range: 0–20, 50, 100 ppm (configurable)
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 56067 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Pump | Yes |
| Humidity | 0-95%RH (no condensation) |
| Display Type | Digital |
| Model | MI-95HCH2O |
| Measuring Range | 10PPM |
| Country of Origin | Made in India |
| Gas Type | CH2O |
•Gas Detected: CH₂O (Formaldehyde)
•Detection Principle: Electrochemical
•Measurement Range: 0–10 ppm / 0–50 ppm / 0–100 ppm (sensor dependent)
•Accuracy: ≤±2% F.S. (varies with sensor model)
•Response Time (T90): 20 seconds
•Repeatability: ≤±1%
•Zero Drift: ≤±1% F.S./year
•Display: 4-digit Nixie tube
•Connection Mode: G1/2 external thread with explosion-proof flexible conduit
•Thread Size: M45 × 2 mm
•Operating Temperature: -20℃ to +50℃
•Humidity Range: 0–95% RH (non-condensing)
•Materials:
•Enclosure: Die-cast aluminium
•Sensor Housing: Aluminium alloy or 316 stainless steel
•Power Supply: 12–36V DC
•Dimensions (L×W×H): 180 × 150 × 90 mm
•Weight: ≤1.6 kg
•Explosion-Proof Rating: Ex d IIC T6 Gb
₹ 47900 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Infrared Sensor |
| Pump | Yes |
| Display Type | Digital |
| Model | MI-95HC6H14 |
| Measuring Range | 0-100% LEL |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Dimension | 180x150x90mm |
| Gas Type | Hexane |
Gas Detected: C₆H₁₄ (Hexane)
Detection Principle: Non-dispersive Infrared (NDIR / Red Infrared)
Installation Method: Wall-mounted, pipeline type, or flow-type (based on detection environment)
Measurement Range: 0–100% LEL
Resolution: 1% LEL
Precision: ±2% F.S.
Output Signal: 4–20 mA, RS485, Relay (optional)
Response Time (T90): ≤ 10 s
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% F.S./year
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Operating Temperature: -30°C to +70°C
Explosion-Proof Grade: Ex d IIC T6
Alarm Mode: Sound and light alarm
Dimensions: 180 × 150 × 90 mm
Recovery Time: ≤ 10 s
Linearity Error: ≤ ±1%
Display: High-brightness Nixie tube display
Gas Unit: PPM
Humidity Range: 0–95% RH
Protection Rating: IP65
Operating Time: 24 hours continuous
Weight: ≤ 1.6 kg
₹ 61097 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Dimensions (L x W x H) | 180x150x90mm |
| Pump | Yes |
| Humidity | 0-95%RH (no condensation) |
| Model | MI-95HPH3 |
| Measuring Range | 100PPM. |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Gas Type | PH3 |
Minimum order quantity: 10 Piece
Gas Detected: PH₃ (Phosphine)
Detection Principle: Electrochemical
Measurement Range: 0–5 / 20 / 50 / 100 ppm (configurable)
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 98150 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Pump | Yes |
| Humidity | 0-95%RH (no condensation) |
| Display Type | Digital |
| Model | MI-95HHF |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Gas Type | HF |
| Dimension | 180 x 150 x 90 mm |
Gas Detected: HF (Hydrogen Fluoride)
Detection Principle: Electrochemical
Measurement Range: 0–10.00 / 50 ppm (configurable)
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 26600 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Pump | Yes |
| Dimensions (L x W x H) | 180x150x90mm |
| Display Type | Digital |
| Measuring Range | 100%LEL |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Model Number | MI-95HC3H8 |
Gas Detected: C₃H₈ (Propane)
Measurement Range: 0–100% LEL
Features:
Data display, with one set of relay output
Power supply: 24V DC
Signal output: 4–20 mA
Product Dimensions: 180 × 150 × 90 mm
Packing Dimensions: 300 × 220 × 150 mm
Gross Weight: 4 kg
Net Weight: 1.6 kg
Operating Temperature: -40°C to +65°C
Humidity: 0–95% RH
Approvals: ATEX
Protection Rating: IP65
₹ 69480 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Dimensions (L x W x H) | 180X150X90mm |
| Pump | Yes |
| Humidity | 0-95%RH (no condensation) |
| Display Type | Digital |
| Model | MI-95HHCN |
| Measuring Range | 100PPM |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Gas Type | HCN |
Gas Detected: HCN (Hydrogen Cyanide)
Detection Principle: Electrochemical
Measurement Range: 0–10 / 50 / 100 ppm (configurable)
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 43728 / Piece Get Latest Price
| Type of Sensors | Electrochemical Sensor |
| Name of Gases Detected | Ammmonia NH3 |
| Brand | Mukta Instuments |
| Model | MI-95HNH3 |
| Display Type | Digital |
| Power Source | Battery |
| Detector Type | Fixed Single Gas |
| Country of Origin | Made in India |
Gas Detected: NH3
Detection Principle: Electrochemical
Measure range: 0-100、200ppm (Available Measuring Range: 0-500、1000ppm)
Accuracy: ≤±2%FS(Specified according to different sensor)
Response time(T90): 20s(Specified according to different sensor)
Repeatability: ≤±1%
Zero shift: ≤±1%(F.S./year)
Display: 4-digits Nixle tube display.
Connection mode: G1/2 external thread explosion-proof flexible pipe
Thread Size: M45*2mm
Temperature: -20℃~50℃
Humidity: 0-95%RH (no condensation)
Material Case: Die-cast aluminium, Sensor Housing: aluminium alloy or 316 stainless steel
Power: 12-36V DC
Dimensions: 180×150×90mm
Weight:≤1.6kg
Explosionproof grade: Ex d IIC T6 Gb
₹ 61767 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Pump | Yes |
| Display Type | Digital |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Gas Type | HCL |
| Dimension | 180 x 150 x 90 mm |
| Model Number | MI-95HHCL |
Gas Detected: HCl (Hydrogen Chloride)
Detection Principle: Electrochemical
Measurement Range: 0–10, 20, 50, 100 ppm (configurable)
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 31756 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Pump | Yes |
| Type of Sensors | Electrochemical |
| Humidity | 95%RH |
| Dimensions (L x W x H) | 180x150x90mm |
| Model | MI-95HCO |
| Dimensions | 180x150x90mm |
| Measuring Range | 0-500ppm |
| Country of Origin | Made in India |
Gas Detected: CO (Carbon Monoxide)
Detection Principle: Electrochemical
Measurement Range: 0–500, 1000, 2000 ppm (configurable)
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminum
• Sensor Housing: Aluminum alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 84239 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Multi Gas |
| Dimensions (L x W x H) | 180x150x90mm |
| Pump | Yes |
| Model | MI-95HMULTI |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Gas Type | O2, NO2, SO2, CH4 |
•Gas Types Detected: O₂, NO₂, SO₂, CH₄
•Measurement Ranges:
•O₂: 0–30% VOL
•NO₂: 0–100 ppm
•SO₂: 0–100 ppm
•CH₄: 0–100% LEL
•Sensor Technology: Electrochemical
•Output Features: Data display with one relay output
•Power Supply: 24V DC
•Signal Output: 4–20 mA
•Product Dimensions (L×W×H): 180 × 150 × 90 mm
•Packaging Dimensions: 300 × 220 × 150 mm
•Net Weight: 1.6 kg
•Gross Weight: 4.0 kg
•Operating Temperature: -40℃ to +65℃
•Humidity Range: 0–95% RH (non-condensing)
•Certifications: ATEX approved
•Protection Rating: IP65
₹ 57100.00 / Piece Get Latest Price
| Type of Sensor | Infrared Sensor |
| Detector Type | Fixed Single Gas |
| Name of Gases Detected | CH4 |
| Model | MI-95HCH4 |
| Display Type | Digital |
| Country of Origin | Made in India |
| Protection Grade | IP65 |
| Humidity | 50%RH |
₹ 35500 / Piece Get Latest Price
| Detector Type | Fixed Single Gas |
| Name of Gases Detected | Methane |
| Brand | Mukta Instruments |
| Type of Sensors | Catalytic Sensor |
| Pump | Yes |
| Model | MI-95HCH4 |
| Display Type | Digital |
| Country of Origin | Made in India |
| Humidity | 95%RH |
₹ 53553 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Infrared Sensor |
| Pump | Yes |
| Humidity | 95%RH |
| Certification | ATEX |
| Resolution | 0.01PPM |
| Display Type | Digital |
| Model | MI-95HCO2 |
| Dimensions | 180x150x90mm |
| Country of Origin | Made in India |
•Gas Detected: CO₂ (Carbon Dioxide)
•Detection Principle: Infrared
•Measurement Range: 0–2000 ppm / 0–5000 ppm / 0–10000 ppm (sensor dependent)
•Accuracy: ≤±2% F.S. (specified according to sensor model)
•Response Time (T90): 20 seconds (specified according to sensor model)
•Repeatability: ≤±1%
•Zero Drift: ≤±1% F.S./year
•Display: 4-digit Nixie tube
•Connection Mode: G1/2 external thread with explosion-proof flexible conduit
•Thread Size: M45 × 2 mm
•Operating Temperature: -20℃ to +50℃
•Humidity Range: 0–95% RH (non-condensing)
•Materials:
•Enclosure: Die-cast aluminium
•Sensor Housing: Aluminium alloy or 316 stainless steel
•Power Supply: 12–36V DC
•Dimensions (L×W×H): 180 × 150 × 90 mm
•Weight: ≤1.6 kg
•Explosion-Proof Rating: Ex d IIC T6 Gb
₹ 41794 / Piece Get Latest Price
| Model | MI-95H1H2 |
| Detector Type | Fixed Gas Detector |
| Pump | Yes |
| Response Time | 20s |
| Name of Gases Detected | H2 |
| Power Source | Plug-In |
| Brand | Mukta Instruments |
| Country of Origin | Made in India |
| Dimension | 180x150x90mm |
•Gas Detected: H₂ (Hydrogen)
•Detection Principle: Electrochemical
•Measurement Range: 0–1000 ppm, 0–2000 ppm, 0–5000 ppm (sensor dependent) (Availble measuring range (0-5000, 40000ppm) (0-100%LEL))
•Accuracy: ≤±2% F.S. (specified according to sensor model)
•Response Time (T90): 20 seconds (specified according to sensor model)
•Repeatability: ≤±1%
•Zero Drift: ≤±1% F.S./year
•Display: 4-digit Nixie tube
•Connection Mode: G1/2 external thread with explosion-proof flexible conduit
•Thread Size: M45 × 2 mm
•Operating Temperature: -20℃ to +50℃
•Humidity Range: 0–95% RH (non-condensing)
•Materials:
•Enclosure: Die-cast aluminium
•Sensor Housing: Aluminium alloy or 316 stainless steel
•Power Supply: 12–36V DC
•Dimensions (L×W×H): 180 × 150 × 90 mm
•Weight: ≤1.6 kg
•Explosion-Proof Rating: Ex d IIC T6 Gb
₹ 36785 / Piece Get Latest Price
| Detector Type | Fixed Gas Detector |
| Warranty | 1 Year |
| Pump | No |
| Response Time | 10 Sec |
| Country of Origin | Made in India |
| Brand | Mukta Instruments |
| Size | 157.8 x 128.8 x 69.6 mm |
₹ 30000 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Name of Gases Detected | LPG |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Pump | Yes |
| Display Type | Digital |
| Model | MI-95HLPG |
| Measuring Range | 100%LEL |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Dimension | 180x140x90mm |
•Gas Detected: LPG (Liquefied Petroleum Gas)
•Measurement Range: 0–100% LEL
•Resolution: 0.01% LEL
•Display & Control: Data display with one set of relay output
•Power Supply: 24V DC
•Signal Output: 4–20 mA
•Product Dimensions (L×W×H): 180 × 150 × 90 mm
•Packing Dimensions: 30 × 22 × 15 cm
•Net Weight: 1.6 kg
•Gross Weight: 4.0 kg
•Operating Temperature: -40℃ to +65℃
•Humidity Range: 0–95% RH (non-condensing)
•Approvals: ATEX
•Protection Rating: IP65
₹ 70000 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Pump | Yes |
| Humidity | 95%RH |
| Resolution | 0.1ppm |
| Display Type | Digital |
| Model | MI-95HCH4S |
| Dimensions | 180x150x90mm |
| Measuring Range | 100ppm |
| Country of Origin | Made in India |
| Type Of Gas | CH4S |
₹ 53720 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Dimensions (L x W x H) | 180x150x90mm |
| Pump | Yes |
| Minimum Detectable Concentration | PPM |
| Humidity | 0-95%RH (no condensation) |
| Input line signal | Light and sound alarm |
| Model | MI-95HCL2 |
| Power Source | Plug-In |
| Country of Origin | Made in India |
Minimum order quantity: 10 Piece
Gas Detected: Cl₂ (Chlorine)
Detection Principle: Electrochemical
Measurement Range: 0–10, 20, 50, 100 ppm (configurable)
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 30079 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Name of Gases Detected | LEL/EX |
| Detector Type | Fixed Single Gas |
| Pump | Yes |
| Type of Sensors | Catalytic Sensor |
| Humidity | 95%RH |
| Resolution | 1%LEL |
| Response Time | 25sec |
| Display Type | Digital |
| Dimensions | 180x150x90mm |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Model Number | MI-95HLEL |
Gas Detected: LEL
Detection Principle: Catalytic Combustion
Measurement Range: 0–100% LEL, 5% Vol
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 57912 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Pump | Yes |
| Humidity | 0-95%RH (no condensation) |
| Display Type | Digital |
| Model | MI-95HN2 |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Gas Type | N2 |
Minimum order quantity: 10 Piece
Gas Detected: N₂ (Nitrogen)
Detection Principle: Electrochemical
Measurement Range: 0–100% Vol
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 31756 / Piece Get Latest Price
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Brand | Mukta Instruments |
| Pump | Yes |
| Usage/Application | Industrial |
| Humidity | 0-95%RH |
| Automation Grade | Automatic |
| Country of Origin | Made in India |
| Dimension | 210x140x92mm |
| Model Number | MI-95HCO |
•Gas Detected: CO (Carbon Monoxide)
•Detection Principle: Electrochemical
•Measurement Range: 0–500 ppm, 0–1000 ppm, 0–2000 ppm (sensor dependent)
•Accuracy: ≤±2% F.S. (specified according to sensor model)
•Response Time (T90): 20 seconds (specified according to sensor model)
•Repeatability: ≤±1%
•Zero Drift: ≤±1% F.S./year
•Display: 4-digit Nixie tube
•Connection Mode: G1/2 external thread with explosion-proof flexible conduit
•Thread Size: M45 × 2 mm
•Operating Temperature: -20℃ to +50℃
•Humidity Range: 0–95% RH (non-condensing)
•Materials:
•Enclosure: Die-cast aluminum
•Sensor Housing: Aluminum alloy or 316 stainless steel
•Power Supply: 12–36V DC
•Dimensions (L×W×H): 180 × 150 × 90 mm
•Weight: ≤1.6 kg
•Explosion-Proof Rating: Ex d IIC T6 Gb
₹ 57744 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Type of Sensors | Electrochemical |
| Pump | Yes |
| Humidity | 0-95%RH |
| Display Type | Digital |
| Model | MI-95H1NO |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Dimension | 180 x 150 x 90 mm |
•Gas Detected: NO (Nitric Oxide)
•Detection Principle: Electrochemical
•Measurement Range: 0–20 ppm, 0–50 ppm, 0–100 ppm, 0–200 ppm (sensor dependent) (availble measuring range 0-500, 1000, 2000ppm)
•Accuracy: ≤±2% F.S. (specified according to sensor model)
•Response Time (T90): 20 seconds (specified according to sensor model)
•Repeatability: ≤±1%
•Zero Drift: ≤±1% F.S./year
•Display: 4-digit Nixie tube
•Connection Mode: G1/2 external thread with explosion-proof flexible conduit
•Thread Size: M45 × 2 mm
•Operating Temperature: -20℃ to +50℃
•Humidity Range: 0–95% RH (non-condensing)
•Materials:
•Enclosure: Die-cast aluminium
•Sensor Housing: Aluminium alloy or 316 stainless steel
•Power Supply: 12–36V DC
•Dimensions (L×W×H): 180 × 150 × 90 mm
•Weight: ≤1.6 kg
•Explosion-Proof Rating: Ex d IIC T6 Gb
₹ 67000 / Piece Get Latest Price
| Measuring range | 0-100 ppm |
| Detector Type | Fixed Single Gas |
| Display Type | Digital |
| Name of Gases Detected | Ethylene C2H4 gas detector |
| Pump | Yes |
| Model | MI-95HC2H4 |
| Brand | Mukta Instruments |
| Power Source | Plug-In |
| Country of Origin | Made in India |
Minimum order quantity: 10 Piece
Detected Gas: C₂H₄ (Ethylene)
Measurement Range: 0–100 PPM
Sensor Principle: Electrochemical
Display: Data display with one set of relay output
Power Supply: 24V DC
Signal Output: 4–20 mA
Product Dimensions: 180 × 150 × 90 mm
Packing Dimensions: 300 × 220 × 150 mm
Gross Weight: 4 kg
Net Weight: 1.6 kg
Operating Conditions:
• Temperature: -40°C to +65°C
• Humidity: 0–95% RH
Approvals: ATEX
Protection Rating: IP65
₹ 36785 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Pump | Yes |
| Humidity | 0-95%RH (no condensation) |
| Display Type | Digital |
| Model | MI-95HO2 |
| Power Source | Plug-In |
| Country of Origin | Made in India |
| Gas Type | O2 |
Gas Detected: O₂ (Oxygen)
Detection Principle: Electrochemical
Measurement Range: 0–25%, 30% Vol
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 75348 / Piece Get Latest Price
| Measuring Range | 100PPM |
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Warranty | 1 Year |
| Pump | Yes |
| Response Time | 20s |
| Display Type | Digital |
| Model | MI-95H3VOC |
| Country of Origin | Made in India |
| Pack Type | Box |
Gas Detected: VOC (Volatile Organic Compounds)
Detection Principle: Electrochemical
Measurement Range: 0–50, 100, 1000 ppm (configurable)
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
₹ 58415 / Piece Get Latest Price
| Brand | Mukta Instruments |
| Detector Type | Fixed Single Gas |
| Pump | Yes |
| Display Type | Digital |
| Model | MI-95HO3 |
| Dimensions | 180x150x90mm |
| Measuring Range | 10PPM |
| Country of Origin | Made in India |
| Gas Type | O3 |
Gas Detected: O₃ (Ozone)
Detection Principle: Electrochemical
Measurement Range: 0–10 / 20 / 50 / 100 ppm (configurable)
Accuracy: ≤ ±2% FS (specified according to sensor)
Response Time (T90): ≤ 20 s (specified according to sensor)
Repeatability: ≤ ±1%
Zero Drift: ≤ ±1% FS/year
Display: 4-digit Nixie tube display
Connection Mode: G1/2 external thread, explosion-proof flexible pipe
Thread Size: M45 × 2 mm
Operating Conditions:
• Temperature: -20°C to +50°C
• Humidity: 0–95% RH (non-condensing)
Material:
• Case: Die-cast aluminium
• Sensor Housing: Aluminium alloy or 316 stainless steel
Power Supply: 12–36V DC
Dimensions: 180 × 150 × 90 mm
Weight: ≤ 1.6 kg
Explosion-Proof Grade: Ex d IIC T6 Gb
Pavankumar Pise (Owner)
Mukta Instruments
First Floor, 22, Gururaj Layout, 1st A Main Road, Vibhutipura Extension, Doddanekundi, Rosedale, Montessori
doddanekkundi, Bengaluru - 560037, Karnataka, India