Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Brand | SAFE GAS |
Power Source | Plug-In |
Display Type | Digital |
Country of Origin | Made in India |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Brand | SAFE GAS |
Model | MI-95 |
Measuring Range | 0-1000ppm |
Dimensions | 180x150x90mm |
Pump | No |
Humidity | 0-95%RH |
Dimensions (L x W x H) | 180x150x90mm |
Measure range: 0-1000ppm
1. Data display, with one set of relay output
2. Power supply: 24V DC
3. Signal output: 4-20mA
4. Dimension of product: 180×150×90mm
5. Dimension of packing: 30x22x15cm
6. Gross Weight: 4KG
7. Net Weight: 1.6KG
8. Working temperature: -40~+65 Humidity: 0-95%RH
9. Approvals: ATEX
10. Protection: IP65
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Brand | SAFE GAS |
Model | MI-95H |
Display Type | Digital |
Measuring Range | 0-10PPM |
Dimensions | 180x150x90mm |
Pump | No |
Gas Detected : O3
Detection Principle : Electrochemical
Install Method :Wall-mounted, piping type, flow-type(according to the detected environment)
Measure Range : 0-10PPM.
Resolution : 0.01PPM
Precision : 2%F.S
Output signal :4-20MA???RS485???relay (optional)
Response Time : ≤10S
Repeatability : ≤±1%
Zero shift : ≤±1%???F.S/year???
Connection mode : G1/2 external thread explosion-proof flexible pipe
Temperature : -30??????70???
Explosion-Proof : Ex d???CT6
Alarm mode : Sound, light
Dimensions :180×150×90mm
Recovery Time : ≤10S
Linearity error : ≤±1%
Display :High light nixie Display tube display
Gas unit : PPM
Humidity : 0-95%RH
Degree of protection :IP65
Operating time : 24h
Weight :≤1.6kg
Additional Information:
Product Details:
Detector Type | Fixed Single Gas |
Name of Gases Detected | Ammmonia |
Brand | Mukta Instuments |
Power Source | Battery |
Display Type | Digital |
Country of Origin | Made in India |
MI-F08 series online NH3 gas detector used the original imported sensor and the ultra low power 32 bit microprocessor, so with the advantages of high precision, good repeatability, stable signal, respond quickly, etc. Possible connected with many controller system, such as PLC, DCS, computer and other, with the function of remote monitor and alarm, data logger and analysis.
Common applications is gas safety inspection and alarm for industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection, etc., where need to inspect the Ammonia (NH3) gas concentration.
Features of the Fixed NH3 gas detector:
4-20mA standard analog signal and RS485 digital signal output, 200~1000HZsignal output, relay output, data restore, data logger(optional);
LED screen displaying the gas concentration, gas type, unit, instrument status etc.
Independent air chamber, the sensor is not required to replace the sensor calibration, automatic identification of key parameters of the sensor
Protection function to prevent high gas concentration attack.
Display the gas concentration in ppm and mg/m3 is selectable.
Infrared remote controller operation;
With the 16bit ADC acquisition chip, designed with four-layer circuit board, so with high anti-interference ability.
With the Ex-proof certificate, the Ex-proof grade is Exd II CT6.
Technical Parameter of the Fixed NH3 gas detector:
Applicable Gas | Ammonia (NH3) |
Detecting Range | 0-20ppm,50ppm,100ppm,200ppm,500ppm or customized |
Resolution | 0.01ppm, 0.1ppm, 1ppm |
Sampling | Diffusion or pump-suction, circulation selectable |
Accuracy | ≤±3%F.S |
Repeatability | ≤±1% |
Zero drift | ≤±1%(F.S/year) |
Sensor Type | Electrochemical sensor |
Sensor Life | 2~3 years |
Response Time (T90) | ≤20s |
Alarming mode | Audible-visual alarm(Optional) |
Operating Environment | Temperature: -30???~60??? (Customized for special demands) Humidity: ≤95%RH (non-condensing); if >90%RH, can add the filter Pressure: 86kPa~106kPa |
Working Voltage | 24V DC(16~30VDC) |
Output Signals | (Standard)Three-wire system 4~20mA standard signals output, available for PLC, DCS, etc; (Optional) Four-wire system RS485 digital signal output; (Optional) Frequency signal 200~1000Hz output; Two-level relay output:220VAC 0.5A, 5VDC 0.5A |
Installation Model | Wall mounted, Pipe type(Thread:M40*1.5 ) |
Material of Body | Cast aluminum |
Explosion-proof Index | Ex d IIC T6 |
Protection Grade | IP66 |
Electrical Interface | 3/4″NPT(Female Screw),1/2″NPT(Female Screw) |
Transmit Distance | ≤2000m |
Dimension | 210 mm×140 mm×92 mm(L×W×H) |
Weight | About 1.5Kg |
Warranty | 12 months |
Standards | GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 |
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Brand | Mukta Instruments |
Usage/Application | Industrial |
Features | Fixed |
Country of Origin | Made in India |
MI-F08 series online gas detector used the original imported sensor and the ultra low power 32 bit microprocessor, so with the advantages of high precision, good repeatability, stable signal, respond quickly, etc. Possible connected with many controller system, such as PLC, DCS, computer and other, with the function of remote monitor and alarm, data logger and analysis.
Common applications is gas safety inspection and alarm for industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection, etc., where need to inspect the Hydrogen Chloride(HCl) gas concentration.
Features:
4-20mA standard analog signal and RS485 digital signal output, 200~1000HZsignal output, relay output, data restore, data logger(optional);
LED screen displaying the gas concentration, gas type, unit, instrument status etc.
Independent air chamber, the sensor is not required to replace the sensor calibration, automatic identification of key parameters of the sensor
Protection function to prevent high gas concentration attack.
Display the gas concentration in ppm and mg/m3 is selectable.
Infrared remote controller operation;
With the 16bit ADC acquisition chip, designed with four-layer circuit board, so with high anti-interference ability.
With the Ex-proof certificate, the Ex-proof grade is Exd II CT6.
Technical Parameter:
Applicable Gas | Hydrogen Chloride(HCl) |
Detecting Range | 0???20ppm,50ppm,100ppm,200ppm,1000ppm or customized |
Resolution | 0.01ppm, 0.1ppm, 1ppm |
Sampling | Diffusion or pump-suction, circulation selectable |
Accuracy | ≤±3%F.S |
Repeatability | ≤±1% |
Zero drift | ≤±1%(F.S/year) |
Sensor Type | Electrochemical sensor |
Sensor Life | 2~3 years |
Response Time (T90) | ≤20s |
Alarming mode | Audible-visual alarm(Optional) |
Operating Environment | Temperature: -30???~60??? (Customized for special demands) Humidity: ≤95%RH (non-condensing); if >90%RH, can add the filter Pressure: 86kPa~106kPa |
Working Voltage | 24V DC(16~30VDC) |
Output Signals | (Standard)Three-wire system 4~20mA standard signals output, available for PLC, DCS, etc; (Optional) Four-wire system RS485 digital signal output; (Optional) Frequency signal 200~1000Hz output; Two-level relay output:220VAC 0.5A, 5VDC 0.5A |
Installation Model | Wall mounted, Pipe type(Thread:M40*1.5 ) |
Material of Body | Cast aluminum |
Explosion-proof Index | Ex d IIC T6 |
Protection Grade | IP66 |
Electrical Interface | 3/4″NPT(Female Screw),1/2″NPT(Female Screw) |
Transmit Distance | ≤2000m |
Dimension | 210 mm×140 mm×92 mm(L×W×H) |
Weight | About 1.5Kg |
Warranty | 12 months |
Standards | GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 |
Product Details:
Minimum Order Quantity | 10 Piece |
Detector Type | Fixed Single Gas |
Name of Gases Detected | LEL/EX |
Brand | SAFE GAS |
Power Source | Plug-In |
Display Type | Digital |
Measuring Range | 0-100% LEL |
Dimensions | 180x150x90mm |
Warranty | 1 year |
Pump | No |
Humidity | 0-95%RH |
Alarm Type | sound |
Resolution | 1%LEL |
Response Time | <25sec |
Country of Origin | Made in India |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Portable Multi Gas |
Brand | SAFE GAS |
Power Source | Battery |
Display Type | Digital |
Country of Origin | Made in India |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Portable Multi Gas |
Brand | SAFE GAS |
Model | MI-2000 |
Power Source | Battery |
Display Type | Digital |
Measuring Range | PM2.5/5/10 0-1000ug/m3 CO 0-1000PPM CO2 0-5000PPM TVOC 0-100PPM Temperature 0-120C Humidity 0-100%RH |
MI2000
PM2.5/5/10 0-1000ug/m3
CO 0-1000PPM
CO2 0-5000PPM
TVOC 0-100PPM
Temperature 0-120C
Humidity 0-100%RH
• Accurate and reliable
• Multi-display mode
• Comprehensive functions
• Data logging
• Mobile recharging and long operation time
• High-quality material
• Screen : 3.5-inch HD LCD screen with resolution 320* 480
• Temperature & Humidity: Temperature: -20-50???, resolution???0.1???; Humidity???0-99%RH, Resolution: 1%RH
• Display : Formula, Concentration Data, Unit, Curve, Battery Power, Time, Temperature, Humidity, Pressure (Optional), Pump Status, Wireless Status, Printer Status, Screenshot Status
• Alarm : Buzzer, red LED and alarm status on the display, fault alarm, pump abnormal alarm, low battery alarm
• Data storage : An independent SD memory card???Max.32G???Measurement data automatic recording function, can customize the record time interval
• Signal output/Data download : RS232 RS485; can be downloaded to the computer in TXT files through USB connection; can be equipped with upper computer software for users to download, store, analyze and print the data
• Charger : Standard Mini-USB charging port equipped with 13V/2A special charger internal printer or5V/2A standard charger external printer
• Battery : High capacity of lithium polymer rechargeable battery, 5400mAh/11.1V (internal printer) or 10000mAh/3.7V (external Bluetooth printer), for single gas: 32h continuously; for multi 6 gases: 24h continuously
• Explosion-proof : Ex ic IIC T3 Gc
• Degree of protection : IP65
• Weight : 3700Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Brand | SAFE GAS |
Model | MI-95H |
Power Source | Plug-In |
Measuring Range | 0-10PPM. |
Dimensions (L x W x H) | 180x150x90mm |
Gas Detected : PH3
Detection Principle : Electrochemical
Install Method :Wall-mounted, piping type, flow-type(according to the detected environment)
Measure Range : 0-10PPM.
Resolution : 0.01PPM
Precision : 2%F.S
Output signal : 4-20MA???RS485???relay (optional)
Response Time : ≤10S
Repeatability : ≤±1%
Zero shift : ≤±1%???F.S/year???
Connection mode : G1/2 external thread explosion-proof flexible pipe
Temperature : -30??????70???
Explosion-Proof : Ex d???CT6
Alarm mode : Sound, light
Dimensions : 180×150×90mm
Recovery Time : ≤10S
Linearity error : ≤±1%
Display :High light nixie Display tube display
Gas unit :PPM
Humidity : 0-95%RH
Degree of protection : IP65
Operating time : 24h
Weight : ≤1.6kg
Additional Information:
Product Details:
Measuring Range | PM2.5 (0-999) |
Usage/Application | Indoor Air Quality |
Brand | mukta Instruments |
Color | Black |
Material | ABS |
· Multi-function CO2 PM2.5 Air quality detector
· Common screen display
· CO2 Technology: infrared (NDIR)
· PM2.5 Sensor technology: Laser Scattering
· Temperature unit between Celsius and Fahrenheit Switch
· 24 hours real time monitoring
· Detection range:
· PM2.5 (0-999 ug/M³)
· CO2 (400-5000 ppm)
· CO2 Alarm value 1000PPM
· CO2 Alarm on /off function
· Power supply:rechargeable Li-battery 3000mah including USB Charging cable
Product Details:
Brand | SAFE GAS |
Detector Type | Fixed Single Gas |
Display Type | Digital |
Measuring Range | 0-100%LEL |
Power Source | Plug-In |
Gas Detection: C3H8
Measure range 0-100%LEL
1. Data display, with one set of relay output
2. Power supply: 24V DC
3. Signal output: 4-20mA
4. Dimension of product: 180×150×90mm
5. Dimension of packing: 30x22x15cm
6. Gross Weight: 4KG
7. Net Weight: 1.6KG
8. Working temperature: -40~+65℃ Humidity: 0-95%RH
9. Approvals: ATEX
10. Protection: IP65
Product Details:
Detector Type | Portable Multi Gas |
Brand | SAFE GAS |
Model | MI-2000 |
Power Source | Battery |
Display Type | Digital |
Measuring Range | CO: 0-1000ppm, H2S: 0-100ppm, O2: 0-30%VOL, LEL: 0-100%LEL |
Dimensions | 205*75*32mm |
Pump | Yes |
Portable pumping multi-gas detector (LEL, CO, H2S, O2)
1. Principle: Electrochemistry LEL: Catalytic combustion (LEL, CO, H2S, O2)
2. Measure range: CO: 0-1000ppm, H2S: 0-100ppm, O2: 0-30%VOL, LEL: 0-100%LEL
3. Resolution: 1ppm(CO), 0.01%VOL(O2), 0.1ppm(H2S), 1%LEL(LEL)
4. Alarm with sound, light and vibration, alarm ponit is settable
5. Large capacity of lithium polymer battery
6. Internal sampling pump, fast response and reliable
7. English language
8. Dimension: 205*75*32mm
9. Weight: 300g
Product Details:
Type of Sensors | Electrochemical Sensor |
Pump | Yes |
Humidity | 0-95%RH |
Certification | ATEX |
Resolution | 0.1PPM |
Methanol Fixed Gas Detector
Gas Detection: CH4O
1.Sensor Principle: Electrochemical
2. Measure range 0-100PPM
3. Data display, with one set of relay output
4. Power supply: 24V DC
5. Signal output: 4-20mA
6. Dimension of product: 180×150×90mm
7. Dimension of packing: 30x22x15cm
8. Gross Weight: 4KG
9. Net Weight: 1.6KG
10. Working temperature: -40~+65℃ Humidity: 0-95%RH
11. Approvals: ATEX
12. Protection: IP65
Product Details:
Pump | No |
Explosion proof grade | Ex ic IIC T3 Gc |
Humidity | 0-99%RH, Resolution: 1%RH |
Sensor Life | 12 months |
Color | Black |
Country of Origin | Made in India |
NOX: 0-5000PPM
CO: 0-20000PPM
CO2: 0-50000PPM
SO2: 0-5000PPM
SENSOR: NOX,CO,SO2:Electrochemical CO2: Infrared
• Accurate and reliable
• Multi-display mode
• Comprehensive functions
• Data logging
• Mobile recharging and long operation time
• High-quality material
• Screen : 3.5-inch HD LCD screen with resolution 320* 480
• Temperature & Humidity: Temperature: -20-50℃, resolution:0.1℃; Humidity:0-99%RH, Resolution: 1%RH
• Display : Formula, Concentration Data, Unit, Curve, Battery Power, Time, Temperature, Humidity, Pressure (Optional), Pump Status, Wireless Status, Printer Status, Screenshot Status
• Alarm : Buzzer, red LED and alarm status on the display, fault alarm, pump abnormal alarm, low battery alarm
• Data storage : An independent SD memory card,Max.32G,Measurement data automatic recording function, can customize the record time interval
• Signal output/Data download : RS232,RS485; can be downloaded to the computer in TXT files through USB connection; can be equipped with upper computer software for users to download, store, analyze and print the data
• Charger : Standard Mini-USB charging port,equipped with 13V/2A special charger(internal printer)or5V/2A standard charger(external printer)
• Battery : High capacity of lithium polymer rechargeable battery, 5400mAh/11.1V (internal printer) or 10000mAh/3.7V (external Bluetooth printer), for single gas: 32h continuously; for multi 6 gases: 24h continuously
• Explosion-proof : Ex ic IIC T3 Gc
• Degree of protection : IP65
• Weight : 3700g
• Warranty : 12 months
Product Details:
Pump | No |
Humidity | 0-95%RH (non-condensing) |
Explosion proof grade | IECEX:, ATEX ,CNEX |
Certification | EMC,ATEX |
Response Time | less than or equal to 60S |
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Brand | Mukta Instruments |
Usage/Application | Industrial |
Features | Fixed |
Color | Orange |
Automation Grade | Automatic |
Country of Origin | Made in India |
MI-F08 series online gas detector used the original imported sensor and the ultra low power 32 bit microprocessor, so with the advantages of high precision, good repeatability, stable signal, respond quickly, etc. Possible connected with many controller system, such as PLC, DCS, computer and other, with the function of remote monitor and alarm, data logger and analysis.
Common applications is gas safety inspection and alarm for industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection, etc., where need to inspect the Methanol CH3OH gas concentration.
Features:
4-20mA standard analog signal and RS485 digital signal output, 200~1000HZsignal output, relay output, data restore, data logger(optional);
LED screen displaying the gas concentration, gas type, unit, instrument status etc.
Independent air chamber, the sensor is not required to replace the sensor calibration, automatic identification of key parameters of the sensor
Protection function to prevent high gas concentration attack.
Display the gas concentration in ppm, %vol and mg/m3 is selectable.
Infrared remote controller operation;
With the 16bit ADC acquisition chip, designed with four-layer circuit board, so with high anti-interference ability.
With the Ex-proof certificate, the Ex-proof grade is Exd II CT6.
Technical Parameter:
Applicable Gas | Methanol (CH4O,CH3OH) |
Detecting Range | 0-50ppm,0-100ppm,0-5%Vol or customized |
Resolution | 0.01ppm(0???100ppm)???0.1%Vol(0-100%Vol) |
Sampling | Diffusion or pump-suction, circulation selectable |
Accuracy | ≤±3%F.S |
Repeatability | ≤±1% |
Zero drift | ≤±1%(F.S/year) |
Sensor Type | Electrochemical sensor(Optional Infrared sensor) |
Sensor Life | 2~3 years |
Response Time (T90) | ≤20s |
Alarming mode | Audible-visual alarm(Optional) |
Operating Environment | Temperature: -30???~60??? (Customized for special demands) Humidity: ≤95%RH (non-condensing); if >90%RH, can add the filter Pressure: 86kPa~106kPa |
Working Voltage | 24V DC(16~30VDC) |
Output Signals | (Standard)Three-wire system 4~20mA standard signals output, available for PLC, DCS, etc; (Optional) Four-wire system RS485 digital signal output; (Optional) Frequency signal 200~1000Hz output; Two-level relay output:220VAC 0.5A, 5VDC 0.5A |
Installation Model | Wall mounted, Pipe type(Thread:M40*1.5 ) |
Material of Body | Cast aluminum |
Explosion-proof Index | Ex d IIC T6 |
Protection Grade | IP66 |
Electrical Interface | 3/4″NPT(Female Screw),1/2″NPT(Female Screw) |
Transmit Distance | ≤2000m |
Dimension | 210 mm×140 mm×92 mm(L×W×H) |
Weight | About 1.5Kg |
Warranty | 12 months |
Standards | GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Brand | Mukta Instruments |
Model | MI-95 A |
Power Source | Plug-In |
Display Type | Digital |
Measuring Range | 0-100% LEL |
Pump | No |
1)Gas Detected: C6H14
2)Detection Principle: Red infrared
3)Install Method: Wall-mounted, piping type, flow-type(according to the detected environment)
4)Measure Range :0-100% LEL
5)Resolution :1%LEL
6)Precision:2% F.S.
7)Output signal :4-20MA RS485 relay (optional)
8)Response Time :≤10S
9) Repeatability :≤±1Zero shift :≤±1 F.S/year
10)Connection mode: G1/2 external thread explosion-proof flexible pipe
11)Temperature:-30 70
12)Explosion-Proof: Ex d CT6
13)Alarm mode: Sound, light
14)Dimensions:180×150×90mm
15)Recovery Time :≤10S
16)Linearity error :≤±1
17)Display: High light nixie tube display
18)Gas unit: LEL
19)Humidity:0-95%RH
20)Degree of protection: IP6522
21)Operating time:24h
22)Weight:≤1.6kg
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | SAFE GAS |
Detector Type | Portable Multi Gas |
Pump | Yes |
Model | MI-3000 |
Measuring Range | CO: 0-1000ppm, H2S: 0-100ppm, O2: 0-30%VOL, LEL: 0-100%LEL |
Model-MI-3000
1. Gas Type: CO, H2S, O2, LEL
2. Sampling method: Pump suction
3. Principle: electrochemical, catalytic combustion
4. Measuring range: CO: 0-1000ppm, H2S: 0-100ppm, O2: 0-30%VOL, LEL: 0-100%LEL
5. Resolution: CO-0.500PPM,H2S-0-100PPM, O2-0.01%VOL, LEL-0-100LEL
6. Response time: ≤ 30 seconds
7. Automatically test and calibration after power on- including reset,maximum value ,minimum value,STEL,TWA value.
8. Unit:PPMand mg/m3 can be switched and displayed by one key , and the concentration value is automatically converted by the system.
9. Display: Monochrome graphic (160x96)
10. Backlight: the back light time can be manually set ,and will be turned on automatically when the alarm is issued.
11. Data record : store 100000sets data.
12. Alarm: 95d Bbuzzer(@30) ,vibration alarm and flashing red LED and alarm status indicator on the screen, alarm latched, diagnostic alarm and battery undervoltage alarm, pump block alarm man down alarm,with early warning and optional real-time remote Bluetooth notification function.
13. Battery: 3.7 v rechargable lithium battery ,battery capacity 2200mA
14. Working hours: more than 15 hours
15. Charger: travel charger with DC interface, charging time: ≥ 4 hours
16. Explosion proof:IECEx, ATEX
17. Protection grade:IP67
18. Working temp:-20° C-+50°C
19. Humidity:0-90%RH
20. Environmental pressure:86-106kpa
21. Size:157*84.5*59.5mm
22. Weight:365g
Additional Information:
Product Details:
Brand | MUKTA INSTRUMENTS |
Model | MI8000 |
Display Type | Digital |
Pump | Yes |
Explosion proof grade | Ex ic IIC T3 Gc |
Oxygen(O2) 0-30%vol
Hydrocarbons NH30-100PPM
Carbon dioxide(CO2) 0-5000PPM
Corbin monoxide (CO) 0-1000PPM
NO 0-100PPM
NO2 0-100PPM
Sulphur Dioxide 0-100PPM
• Accurate and reliable
• Multi-display mode
• Comprehensive functions
• Data logging
• Mobile recharging and long operation time
• High-quality material
• Screen : 3.5-inch HD LCD screen with resolution 320* 480
• Temperature & Humidity: Temperature: -20-50℃, resolution:0.1℃; Humidity:0-99%RH, Resolution: 1%RH
• Display : Formula, Concentration Data, Unit, Curve, Battery Power, Time, Temperature, Humidity, Pressure (Optional), Pump Status, Wireless Status, Printer Status, Screenshot Status
• Alarm : Buzzer, red LED and alarm status on the display, fault alarm, pump abnormal alarm, low battery alarm
• Data storage : An independent SD memory card,Max.32G,Measurement data automatic recording function, can customize the record time interval
• Signal output/Data download : RS232,RS485; can be downloaded to the computer in TXT files through USB connection; can be equipped with upper computer software for users to download, store, analyze and print the data
• Charger : Standard Mini-USB charging port,equipped with 13V/2A special charger (internal printer)or5V/2A standard charger(external printer)
• Battery : High capacity of lithium polymer rechargeable battery, 5400mAh/11.1V (internal printer) or 10000mAh/3.7V (external Bluetooth printer), for single gas: 32h continuously; for multi 6 gases: 24h continuously
• Explosion-proof : Ex ic IIC T3 Gc
• Degree of protection : IP65
• Weight : 3700g
• Warranty : 12 months
Product Details:
Brand | SAFE GAS |
Model | MI-2000 |
Display Type | Digital |
Pump | Yes |
Alarm Type | Alarm with sound, light and vibration, alarm point is settable |
Product Details:
Model Name/Number | MI-509 |
Usage/Application | Indoor Air Quality |
Brand | MUKTA INSTRUMENTS |
Color | BLACK |
Material | ABS |
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Name of Gases Detected | Ethylene C2H4 gas detector |
Brand | Mukta Instruments |
Model | MI-95H |
Power Source | Plug-In |
Display Type | Digital |
Technical Parameter:
1.Applicable Gas: Ethylene (C2H4)
2.Detecting Range:0-20ppm, 200ppm, 500ppm,1000ppm,1500ppm 20000ppm or customized
3.Installation Means: Wall mounted, Pipe type (Thread:M40*1.5 )
4. Data display, with one set of relay output
5. Power supply: 24V DC
6. Signal output: 4-20mA
7. Dimension of product: 180×150×90mm
8. Dimension of packing: 30x22x15cm
9. Gross Weight: 4KG
10. Net Weight: 1.6KG
11. Working temperature: -40~+65 Humidity: 0-95%RH
12. Approvals: ATEX
13. Protection: IP65
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Brand | SAFE GAS |
Model | MI-95 |
Display Type | Digital |
Measuring Range | 0-100ppm |
Dimensions | 180x150x90mm |
Pump | No |
Humidity | 0-95%RH |
Gas Detection: CH4S
Measure range: 0-100ppm Resolution:0.01ppm
1. Data display, with one set of relay output
2. Power supply: 24V DC
3. Signal output: 4-20mA
4. Dimension of product: 180×150×90mm
5. Dimension of packing: 30x22x15cm
6. Gross Weight: 4KG
7. Net Weight: 1.6KG
8. Working temperature: -40~+65??? Humidity: 0-95%RH
9. Approvals: ATEX
10. Protection: IP65
Additional Information:
Product Details:
Detector Type | Portable Single Gas |
Brand | SAFE GAS |
Model | MI-1200 |
Power Source | Battery |
Measuring Range | 0-100PPM |
Dimensions | 131*83*35mm |
Dimensions (L x W x H) | 131*83*35mm |
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Portable Single Gas |
Name of Gases Detected | Methane |
Brand | SAFE GAS |
Model | MI-1200 |
Power Source | Battery |
Display Type | Digital |
Measuring Range | 0-100%LEL |
Pump | No |
1. Sampling method: Diffusion
2. Detected gas: CH4
3. Detection principle: catalytic combustion
4. Measure range: CH4 0-100%LEL
5. Precision: 5% F.S.
6. Display: Monochrome dot matrix 128*128 LCD graphic display.
7. Backlight: Time of backlight is settable, when alarm the backlight will be auto on.
8. Data recording: Storage capacity of over one hundred thousand sets. Interval time ranges from 10~3600 seconds are settable. (Optional function)
9. Alarm recording: can record 10000 set alarm records, the record can be checked on the device. (Optional function)
10. Language: English
11. Alarm type: sound, light, vibration.
12. Battery: 3.7V rechargeable lithium battery, with a capacity of 2300mAh.
13. Working Time: 14h continuously (common 4 gases). 200h(without LEL sensor)
14. Charger: travel charger with USB. Charging time: 4~6h
15. Explosion-proof grade: Explosion-proof grade: ExiaⅡCT3
16. Protection grade: Protection grade: IP65
17. Working temperature: Working temperature:-20℃~50℃
18. Working humidity: 0-90%RH (Non-condensing, a filter dryer is needed in an environment of humidity
19. Housing Material: Housing Material: ABS+ leather case
20. Dimension: Dimension: 131*83*35mm(length*width*height)
21. Weight: Weight:240g
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Name of Gases Detected | LPG |
Brand | SAFE GAS |
Model | MI-95H |
Power Source | Plug-In |
Display Type | Digital |
Measuring Range | 0-100%LEL |
LEL FIXED GAS DETECTOR
Measure range: 0-100%LEL Resolution:1%LEL
1. Sensor Principle: Catalytic combustion
2. Data display, with one set of relay output
3. Power supply: 24V DC
4. Signal output: 4-20mA
5. Dimension of product: 180×150×90mm
6. Dimension of packing: 30x22x15cm
7. Gross Weight: 4KG
8. Net Weight: 1.6KG
9. Working temperature: -40~+65℃ Humidity: 0-95%RH
10. Approvals: ATEX
11. Protection: IP65
Additional Information:
Product Details:
Brand | MUKTA INSTRUMENTS |
Model | MI-98 |
Display Type | Digital |
Pump | Yes |
Humidity | 0-95%RH(no condensation) |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | MI-AQMS06 |
Warranty | 1 Year |
Usage/Application | Hvac |
Brand | Mukta Instruments |
Product Details:
Minimum Order Quantity | 1 Piece |
Name of Gases Detected | Hydrogen |
Brand | SAFE GAS |
Model | MI-95H |
Power Source | Plug-In |
Dimensions (L x W x H) | 180x150x90mm |
Minimum Detectable Concentration | PPM |
Input line signal | Light and sound alarm |
Country of Origin | Made in India |
Additional Information:
Product Details:
Detector Type | Portable Single Gas |
Brand | SAFE GAS |
Model | MI-2000 |
Power Source | Battery |
Display Type | Digital |
Measuring Range | 0-10000PPM |
PORTABLE SINGLE GAS DETECTOR
GAS detected: VOC(FOR EXHAUST GAS)
1. Measure range: VOC 0-10000PPM
2. Detection principle: PID
3. Alarm with sound, light and vibration, alarm point is settable
4. Large capacity of lithium polymer battery
5. Detect the VOC gas concentration in the air
6. Internal sampling pump, fast response and reliable
7. Data can be transferred to PC
8. English language
9. Dimension: 205*75*32mm
10.Weight: 300
Product Details:
Detector Type | Portable Multi Gas |
Brand | SAFE GAS |
Model | MI-95H |
Power Source | Plug-In |
Dimensions (L x W x H) | 180x150x90mm |
1. Gas Detection: O2, NO2, SO2, CH4
2. Measure range: O2 0-30%VOL, NO2 0-100PPM, SO2 0-100PPM, CH4 0- 100%LEL
3. Sensor: Electrochemical
4. Data display, with one set of relay output
5. Power supply: 24V DC
6. Signal output: 4-20mA
7. Dimension of product: 180×150×90mm
8. Dimension of packing: 30x22x15cm
9. Gross Weight: 4KG
10. Net Weight: 1.6KG
11. Working temperature: -40~+65 Humidity: 0-95%RH
12. Approvals: ATEX
13. Protection: IP65
Product Details:
Detector Type | Portable Single Gas |
Brand | SAFE GAS |
Model | MI-1200 |
Power Source | Battery |
Display Type | Digital |
Measuring Range | 0-100%LEL |
Dimensions | 131x83x35mm |
Model:MI-1200
1.Sampling: Diffusion
2.Measure range: C6H14: 0-100%LEL
3.Sensor: catalytic combustion
4. Data logging: Data logging with adjustable interval, and available for data downloading to PC through USB cable.
5.Precision: ≤±3%F.S. (higher precision is available)
6. Zero shift: ≤±1%(F.S./year)
7.Display: LCD dot matrix display, with display of gas type, real time gas concentration, gas unit.
8.Backlight: Time of backlight is settable, when alarm the backlight will be auto on.
9.Temperature: -20℃~50℃
10. Humidity: 0-95%RH (non-condensing)
11. Explosion-Proof: ExiaⅡCT3
12.Degree of protection : IP65
13. Alarm: Sound: 85dB
Light: LED, low alarm: blue, high alarm: red
Alarm point is settable according to customer requirement.
14. Battery : 3.6V 2300mAh lithium polymer rechargeable battery, for toxic gas: 14h continuously, for combustible gas: 10 h continuously, charging time: 4-6 h
15. Dimensions : 131x83x35mm
16. Weight : 240g
17. Approval : CE, CNEX explosion proof certificate
Product Details:
Brand | MUKTA INSTRUMENTS |
Model | MI-1200 |
Display Type | Digital |
Pump | No |
Alarm Type | can record 10000 set alarm records, the record can be checked on the device |
1. Sampling method: Diffusion Detected gas: O2 & O3 Measure range: O3: 0-50ppm O2:0-30%VOL
2. Display: Monochrome dot matrix 128*128 LCD graphic display.
3. Backlight:Time of backlight is settable,when alarm the backlight will be auto on.
4. Data recording: Storage capacity of over one hundred thousand sets.
5. Interval time ranges from 10~3600 seconds are settable.(Optional function extra cost )
6. Alarm recording: can record 10000 set alarm records, the record can be checked on the device. Language: English
7. Alarm type: sound, light, vibration.
8. Battery: 3.7V rechargeable lithium battery, with a capacity of 2300mAh.
9. Working Time: 14h continuously (common 4 gases). 200h(without LEL sensor) Charger: travel charger with USB. 10. Charging time: 4~6h Explosion-proof grade:
11. Explosion-proof grade: ExiaⅡCT3 Protection grade: Protection grade: IP65 Working temperature: Working temperature:-20℃~50℃
12. Working humidity: 0-90%RH (Non-condensing, a filter dryer is needed in an environment of humidity Housing Material: Housing Material: ABS+ leather case Dimension: Dimension: 131*83*35mm(length*width*height)
13. Weight: Weight:240g
Product Details:
Detector Type | Portable Multi Gas Detector |
Brand | MUKTA INSTRUMENTS |
Model | MI8000 |
Display Type | Digital |
Pump | Yes |
Gas detected:PM2.5,PM10,TVOC,CH2O,SO2,NO2,O2,O3,CO,CO2,RH,TEMPERATURE
Measuring Range: M10(PM2.5/5/10 0-1000ug/m3, TVOC 0-100PPM, CH2O 0-10PPM, SO2 0-20PPM, NO2 0-20PPM, O2 0-30%VOL, O3 0-10PPM CO 0-500PPM, CO2 0-5000PPM, RH 0-100%RH, Temperature 0-120C
• Accurate and reliable
• Multi-display mode
• Comprehensive functions
• Data logging
• Mobile recharging and long operation time
• High-quality material
• Screen : 3.5-inch HD LCD screen with resolution 320* 480
• Temperature & Humidity: Temperature: -20-50℃, resolution:0.1℃; Humidity:0-99%RH, Resolution: 1%RH
• Display : Formula, Concentration Data, Unit, Curve, Battery Power, Time, Temperature, Humidity, Pressure (Optional), Pump Status, Wireless Status, Printer Status, Screenshot Status
• Alarm : Buzzer, red LED and alarm status on the display, fault alarm, pump abnormal alarm, low battery alarm
• Data storage : An independent SD memory card,Max.32G,Measurement data automatic recording function, can customize the record time interval
• Signal output/Data download : RS232,RS485; can be downloaded to the computer in TXT files through USB connection; can be equipped with upper computer software for users to download, store, analyze and print the data
• Charger : Standard Mini-USB charging port,equipped with 13V/2A special charger(internal printer)or5V/2A standard charger(external printer)
• Battery : High capacity of lithium polymer rechargeable battery, 5400mAh/11.1V (internal printer) or 10000mAh/3.7V
• Explosion-proof : Ex ic IIC T3 Gc
• Degree of protection : IP65
• Weight : 3700g
Product Details:
Name of Gases Detected | H2 |
Brand | safe gas |
Model | MI-95H |
Power Source | Plug-In |
Country of Origin | Made in India |
Product Details:
Brand | SAFE GAS |
Model | MI-1200 |
Display Type | Digital |
Pump | No |
Humidity | 0-95%RH (non-condensing) |
Model:MI-1200
1.Sampling: Diffusion
2.Measure range: SO2 0-100PPM,NO2 0-100PPM,NH3 0-100PPM
3.Sensor: Electrochemical
4. Data logging: Data logging with adjustable interval, and available for data downloading to PC through USB cable.
5.Precision: ≤±3%F.S. (higher precision is available)
6. Zero shift: ≤±1%(F.S./year)
7.Display: LCD dot matrix display, with display of gas type, real time gas concentration, gas unit.
8.Backlight: Time of backlight is settable, when alarm the backlight will be auto on.
9.Temperature: -20℃~50℃
10. Humidity: 0-95%RH (non-condensing)
11. Explosion-Proof: ExiaⅡCT3
12.Degree of protection : IP65
13. Alarm: Sound: 85dB
Light: LED, low alarm: blue, high alarm: red
Alarm point is settable according to customer requirement.
14. Battery : 3.6V 2300mAh lithium polymer rechargeable battery, for toxic gas: 14h continuously, for combustible gas: 10 h continuously, charging time: 4-6 h
15. Dimensions : 131x83x35mm
16. Weight : 240g
17. Approval : CE, CNEX explosion proof certificate
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Gas Detector |
Warranty | 1 YEAR |
Pump | Yes |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Detector Type | Fixed Single Gas |
Brand | Mukta Instruments |
Usage/Application | Industrial |
Features | Fixed |
Color | Orange |
Automation Grade | Automatic |
Country of Origin | Made in India |
MI-F08 series fixed Carbon Monoxide CO gas detector used the original imported sensor and the ultra low power 32 bit microprocessor, so with the advantages of high precision, good repeatability, stable signal, respond quickly, etc. Possible connected with many controller system, such as PLC, DCS, computer and other, with the function of remote monitor and alarm, data logger and analysis.
Common applications is gas safety inspection and alarm for industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection, etc., where need to inspect the Carbon Monoxide CO gas concentration.
Features:
4-20mA standard analog signal and RS485 digital signal output, ModBus RTU output, 200~1000HZsignal output, relay output, data restore, data logger(optional);
LED screen displaying the gas concentration, gas type, unit, instrument status etc.
Independent air chamber, the sensor is not required to replace the sensor calibration, automatic identification of key parameters of the sensor
Protection function to prevent high gas concentration attack.
Display the gas concentration in ppm and mg/m3 is selectable.
Infrared remote controller operation;
With the 16bit ADC acquisition chip, designed with four-layer circuit board, so with high anti-interference ability.
With the Ex-proof certificate, the Ex-proof grade is Exd II CT6.
Technical Parameter:
Detecting Range | 0-20ppm,50ppm,100ppm,200ppm,500ppm,1000ppm,2000ppm,5000ppm,10000ppm or customized |
Operating Environment | Temperature: -30???~60??? (Customized for special demands) Humidity: ≤95%RH (non-condensing); if >90%RH, can add the filter Pressure: 86kPa~106kPa |
Working Voltage | 24V DC(16~30VDC) |
Output Signals | (Standard)Three-wire system 4~20mA standard signals output, available for PLC, DCS, etc; (Optional) Four-wire system RS485 digital signal output; (Optional) Frequency signal 200~1000Hz output; Two-level relay output:220VAC 0.5A, 5VDC 0.5A |
Installation Model | Wall mounted, Pipe type(Thread:M40*1.5 ) |
Material of Body | Cast aluminum |
Explosion-proof Index | Ex d IIC T6 |
Protection Grade | IP66 |
Electrical Interface | 3/4″NPT(Female Screw),1/2″NPT(Female Screw) |
Transmit Distance | ≤2000m (If more than 2000m, can add the repeater.) |
Dimension | 210 mm×140 mm×92 mm(L×W×H) |
Weight | About 1.5Kg |
Warranty | 12 months |
Standards | GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 |
Resolution | 0.01ppm,0.1ppm,1ppm |
Sampling | Diffusion or pump-suction, circulation selectable |
Accuracy | ≤±3%F.S |
Repeatability | ≤±1% |
Zero drift | ≤±1%(F.S/year) |
Sensor Type | Electrochemical sensor |
Sensor Life | 2~3 years |
Response Time (T90) | ≤20s |
Alarming mode | Audible-visual alarm(Optional) |
Additional Information:
Product Details:
Minimum Order Quantity | 1 PIECE |
Measuring Range | 0-5000ppm |
Brand | MUKTA INSTRUMENTS |
Output Current ( in mA) | 2400mAh lithium battery |
Dimensions | 10*8.6*4.3cm |
Detection Principle | NDIR |
Operating Humidity | 20-80% |
• Co2 monitor
• Measuring Range:0-5000ppm
• Resolution:1ppm
• Sensor: NDIR
• Display: High Quality numeric LCD display
• Material: High Grade ABS, matt finished
• Battery:2400mah lithium battery
• Operating Temperature: 0 TO 50°C
• USB Charging
• Weight: 195 g
• Monitors Temperature and Humidity
Product Details:
Detector Type | Fixed Single Gas |
Brand | SAFE GAS |
Model | MI-95H |
Power Source | Plug-In |
Display Type | Digital |
Measuring Range | 0-10PPM. |
Gas Detected : CH2O
Detection Principle : Electrochemical
Install Method :Wall-mounted, piping type, flow-type(according to the detected environment)
Measure Range : 0-10PPM.
Resolution : 0.01PPM
Precision : 2%F.S
Output signal : 4-20MA???RS485???relay (optional)
Response Time : ≤10S
Repeatability : ≤±1%
Zero shift : ≤±1%???F.S/year???
Connection mode :G1/2 external thread explosion-proof flexible pipe
Temperature : -30??????70???
Explosion-Proof : Ex d???CT6
Alarm mode : Sound, light
Dimensions : 180×150×90mm
Recovery Time : ≤10S
Linearity error : ≤±1%
display : High light nixie Display tube display
Gas unit : PPM
Humidity : 0-95%RH
Degree of protection : IP65
Operating time : 24h
Weight :≤1.6kg